Digital Water Quality Meter Tester | Toc Cod Tds Temp Envig AVT01

Digital Water Quality Meter Tester | Toc Cod Tds Temp Envig AVT01

Categories: Laboratories, Others, Agribusiness
  • Description

Description

Product Description:

– Better test coverage: With so many things that can be tested in drinking water, it can be overwhelming and expensive to choose a lab test. Use this water quality meter to get an approximation in hierarchical levels. It covers general levels of contaminants not only related to inorganic matter (TDS), but more importantly, related to organic matter (microbiology, volatile organic compounds, and pesticides). It is the first and so far only consumer device on the market with instant testing for organic contamination.

– More important than a TDS meter: TOC (Total Organic Carbon) and COD (Chemical Oxygen Demand) reflect contamination of organic matter in drinking water, including natural organic matter such as algae, bacteria, viruses, or other microbiological contaminants, as well as synthetic or volatile organics (SOC/VOCs) such as pesticides, herbicides, or THMS. TOC reacts with chlorine and forms carcinogenic disinfection byproducts (DBPs). Know and control TOC before chlorination of your well water.

– Instant lab-quality readings: Previously, TOC and COD readings required testing in a professional lab or through expensive water quality analyzers. With innovative UV spectral technology, you can use this water quality meter and get lab-quality readings in seconds, without the expensive and cumbersome water quality test.

– Companion to any water filtration system: This water quality meter is a great companion to any water filtration system, giving you an unmistakable change in water quality before and after the use of a water filtration system, the replacement of water filter cartridges, or the effects of using a new water filter or dispenser. It can also be used to check for biofouling formation in your reverse osmosis system.

– Anywhere Water Quality Guarantee: With its pocket-sized and intuitive design, you can take the water quality meter anywhere you want to check the quality of drinking water. This can be used by water professionals as a sensing device. It can also be taken on an expedition where drinking water may come from a clear river or lake. Readjust it with distilled water. IT PREVENTS BUBBLES IN THE SENSOR HEAD IN BOTH CALIBRATION AND TESTING BY GENTLY SHAKING THE METER WHILE THE HEAD IS IN THE SAMPLE WATER.

More Comprehensive Water Quality Testing with TOC and COD
Get TOC and COD in seconds instead of hours or days.
Envig’s TOC meter can be used to detect and monitor the quality of drinking water at the original source or the filtration effect of water filtration systems in important dimensions that reflect organic contamination, oxidizable contaminants, and dissolved solids in the water. With innovative spectral technology, advanced algorithms, and leading components, this precision device provides lab-quality TOC and COD readings in seconds, instead of hours or even days of professional lab work, and marks a new era of instant water quality monitoring for organic and oxidizable contaminations, for enthusiasts, families and professionals alike.

Total Organic Carbon (TOC)
Total Organic Carbon (TOC) is a measure of the total amount of carbon in organic compounds. TOC in source waters comes from the decomposition of natural organic matter, such as microorganisms, as well as synthetic sources such as pesticides or chemical pollutants. It includes both Purgeable Organic Carbon (also known as VOCs, Volatile Organic Carbon) and Non-Purgeable Organic Carbon.

Chemical Oxygen Demand (COD)
Chemical Oxygen Demand (COD) is an indicative measure of the amount of oxygen that can be consumed by oxidizable compounds in water. It is used to quantify the presence of such oxidizable compounds. Organic compounds are oxidizable, therefore there is usually a correlation between COD and TOC. However, COD can also vary and show higher readings due to the presence of oxidizable inorganic contaminants, such as ammonia or nitrite.

First-line
defense A quick and convenient way to determine the degree of organic, oxidizable, and dissolved contamination in general.

– Covers all organic areas of a typical test report (microbes, SOCs, and VOCs) with TOC and COD, and the level of inorganic salts with TDS. It allows for a hierarchical approach for additional testing if needed.
– Detects in real time and continuously.
– Rotating display showing all four indicators.
– Colored LED lights to indicate water quality and provide peace of mind (blue, orange, red).
– Take it with you anywhere you want to test the water quality.

Dimensions: 6.5″ x 0.75″ x 0.83″ (165 x 19 x 21mm)

Operating temperature: 50 – 104 °F / 10 – 40 °C

Detection range (unit: mg/L)

TOC: Detection Range: 0-10, Maximum Error: 10%FS, Reading Resolution: 0.1

COD: Detection Range: 0-10, Maximum Error: 10%FS, Reading Resolution: 0.1

TDS: Detection Range: 0-1000, Maximum Error: 10%FS, Reading Resolution: 1

TEMP: Detection Range: 0-80°C, Maximum Error: +/-0.5°C, Reading Resolution: 0.1°C

What’s in the box:
Water quality meter (2 AAA batteries not included), user manual.

Frequently Asked Questions (FAQs)

I get readings that are apparently incorrect.
If there are even small bubbles attached to the head of the detector, this can lead to errors in the reading. To avoid this, every time you place the meter in a water sample, shake it lightly to remove all bubbles.

Readings on the same water sample vary greatly and are apparently incorrect.
This is mainly due to bubbles attached to the sensor head at the time of calibration. Recalibrating will likely fix the problem.

Is it waterproof?
The sensor head is waterproof, but not the entire meter body. Just dip the meter head into the water sample. Water should never reach the level of the power/test keys. You can also use the lid as a holder for the water sample.

     

    ------------------

    Would you like to obtain information about this product?

    Related products

    • Calibration Solution 250ml Buffer Standard Ph 10.01

    • Digital Salinity Meter Automatic Salt Concentration EN901

    • Digital Lighting Light Meter for Ambient Temperature AP-881D

    • Digital Pressure Gauge Gas Hvac Air Differential Gauge YW-721

    Contact Us

    Phone number: +1 786 209 1702
    Email: info@northindustriallab.com

    © Copyright - North Industrial Lab LLC - Enfold WordPress Theme by Kriesi
    Link to: Portable Oscilloscope Hds2102s 100 Mhz 2 Channels Owon HDS2102S Link to: Portable Oscilloscope Hds2102s 100 Mhz 2 Channels Owon HDS2102S Portable Oscilloscope Hds2102s 100 Mhz 2 Channels Owon HDS2102S Link to: Hantek Digital Automatic 8 Channel Oscilloscope Data Usb Hantek 1008C PC Black Link to: Hantek Digital Automatic 8 Channel Oscilloscope Data Usb Hantek 1008C PC Black Hantek Digital Automatic 8 Channel Oscilloscope Data Usb Hantek 1008C PC Bl...
    Scroll to top Scroll to top Scroll to top

    Powered by WhatsApp Chat