Description
The Milwaukee MI407 PRO light meter is for users who demand fast, reliable, and repeatable results with ease of use.
The Milwaukee MI407 PRO light meter features manual zero-point calibration and fast operation in a rugged design.
The Milwaukee PRO photometer is ideal for users in laboratory, water treatment and conditioning, environmental, aquaculture, and applications. This meter is also ideal for educators who want their students to learn the basics of water quality analysis to apply in the real world.
The Milwaukee PRO light meter offers:
VELOCITY
The MI407 microprocessor delivers fast results with an accuracy of ± 0.09 mg/L to 1.50 mg/L and is repeatable.
EASY TO USE AND RESISTANT
This robust meter is designed to withstand shocks. Its low-maintenance design combined with easy-to-use reagents makes the MI407 ideal for everyone from educators and aquaculture, water conditioning, environmental professionals to water treatment and food processing.
FEATURES
– Fast, easy-to-read results with a large digital LCD readout.
– Accuracy of ± 0.09 mg/L @ 1.50 mg/L and a range of 0.00 to 3.00 mg/L (NH3-N).
– Lightweight and portable.
– Easy measurement: Simply mix the reagent into the sample, shake gently, insert the cuvette, zero the meter, and press read.
– Simple and easy reagent packs or liquid bottles.
– Simple 1-2-3 instructional steps.
– Automatic shut-off after 10 minutes of inactivity, 9 volts (battery included).
– Adaptation of the Nessler Method.
BUILT-IN TIMER
MI407 has a built-in timer that ensures that the proper reaction time is used for the chemical reaction. At the end of the timer, the meter will automatically take the reading. This feature ensures consistency across multiple users.
BUCKET CHAMBER
The MI407 has an indexing indentation built into the meter: the meter has an indentation that allows for a lock and key adjustment with the bucket lid. This ensures that the cuvette is consistently indexed (in the same position) to maintain the same path length for accurate results.
ERROR MESSAGES
The MI407 has built-in error message display alerts. This helps the user ensure that no mistakes are made in the testing process. Messages include unlimited, over-range and under-range, light source errors, and zero calibration error to ensure the user has the most accurate error-free readings.
CALIBRATION
The MI407 has an easy-to-use zero-point calibration. Simply insert the sample cuvette without reacting into the chamber, index the cuvette and press the zero button. Your calibration is complete.
SPECS
– Ammonia Photometer, Low Range: 0.00 to 3.00 mg/L (NH3-N)
– Resolution: 0.01 mg/L
– Accuracy ± 0.09 mg/L @ 1.50 mg/L
– Method: Adaptation of the Nessler Method
– Light source: 466 nm blue LED
– Light detector: silicon photocell and 466nm narrowband interference filter
– Operating Environment: 0 to 50 C 32 to 122 F/Max. RH 100%
– Battery Type: 1 X 9V
– Automatic shut-off: after 10 minutes of inactivity
– Meter Dimensions/Weight: 7.5″ x 4.1″ x 2″ / 0.84 lbs.
– Dimensions/Packaging Weight: 12″ x 11″ x 4.5″ / 2.7 lbs.
– Dimensions/Meter Weight: 191mm x 107mm x 51mm/1.22kg.
– Dimensions / Packaging weight: 305 mm x 280 mm x 115 mm / 1.5 kg.