• English English English en
You can call us at: +1 786 209 1702
  • Shopping Cart Shopping Cart
    0Shopping Cart
North Industrial Lab LLC
  • Home
  • Company
  • Instrumentation
  • Industries
  • Contact
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu
Network Analyzer Networks 100khz To 960mhz Signal Generator TinySA

Network Analyzer Networks 100khz To 960mhz Signal Generator TinySA

Categories: Electric, Power Quality Analyzers
  • Description

Description

TinySA Portable Spectrum Analyzer, SEESII Updated V0.3.1 100kHz to 960MHz Portable Tiny Frequency Analyzer MF/HF/VHF UHF Input, 2.8 Inch Touch Screen Signal Generator with ESD Protection Function

Frequency
Range Tiny spectrum analyzer with two inputs, high-quality MF/HF/VHF input for 0.1 MHz-350 MHz, lower-quality UHF input for 240 MHz-960 MHz. Switchable resolution bandpass filters for both ranges between 2.6kHz and 640kHz. Color display showing 290 scan points covering the entire range of low or high frequencies. The tinySA contains all the components of a conventional heterodyne scanning spectrum analyzer.

Built-in
calibration signal generator When not used as a spectrum analyzer, it can be used as a signal generator, MF/HF/VHF sine output between 0.1 MHz and 350 MHz, UHF square wave output between 240 MHz and 960 MHz. Built-in calibration signal generator used for automatic self-test and low-input calibration.

Tiny spectrum analyzers and ESD
function Switchable resolution bandpass filters for both ranges between 2.6 kHz and 640 kHz. Color display showing 290 scan points covering the full range of low or high frequency. Built-in rechargeable battery that allows a minimum of at least 2 hours of portable use. The performance of the latest version 3.1 of 2021 will be more stable and responsive, with a new ESD protection function that allows the product to have a higher anti-static level and longer service life.

PC
Control Connected to a PC via USB, it becomes a PC-controlled spectrum analyzer. The USB interface implements the Serial over USB (CDC) protocol and there is a large set of commands that can be invoked through the serial interface. These commands can be used to perform measurements or update internal settings. The driver for Windows will install automatically after connecting to a Windows PC. The driver for Linux is built into the kernel.

-Specifications-User
interface:
-Screen resolution 320*240 pixels-Diagonal
screen 2.8″
-16 bits per RGB pixels-Resistive

touch control-Jog
switch control-USB serial port control-Optional
USART TTL port (SW not yet implemented) on the internal
PCB-Linear power supply to avoid switching noise.

Low input mode specifications:
-Input frequency range from 100kHz to 350MHz (with some limitations up to 10kHz)
-Input impedance of 50 ohms when input attenuation is set to 10dB or more.
-Manual and automatic input attenuation selectable between 0dB and 31dB in 1 dB steps
-Absolute maximum input level of +10dBm with internal attenuation of 0dB
-Short-term absolute maximum input power of +20dBm with internal attenuation of 30dB
-Suggested maximum input power of +5dBm with internal attenuation in auto mode
-For best measurements, keep the input power below -25dBm
-+15dBm third-order modulation (IIP3) product input intercept point with 0dB internal attenuation
-1dB to -1dBm compression point with 0dB internal attenuation
-Power detector resolution of 0.5dB and linearity versus frequency of +/-1dB
-Absolute power level accuracy after power level calibration of +/- 1dB
-Lowest perceptible signal using 30kHz resolution bandwidth of -102dBm-Frequency
accuracy equal to selected resolution
bandwidth–Phase noise of -90dB/Hz at 100kHz compensation and -115dB/Hz at 1MHz compensation-Pulse-free
dynamic range when using 30kHz resolution bandwidth of 70dB
-Manually selectable resolution filters of 3, 10, 30, 100, 300, 600kHz. Automatic selection of one of 57 resolution filters.
-Screen resolution of 51, 101, 145 or 290 measuring points.
-Scanning speed of more than 1000 points/second using the highest resolution filters.
-Automatic optimization of actual scan points to ensure coverage of the entire scanning range, regardless of the chosen
resolution bandwidth-Stimulus suppression option to evaluate whether certain signals are generated internally or are actually present in the input
signal-After a small HW modification it is possible to hear demodulated audio

High Specification of Input Mode:
-Input frequency range from 240 MHz to 960 MHz
-Input impedance is frequency dependent and deviates from 50 ohm
-As there is no input band filter, strong input signals outside the range of 240 MHz to 960 MHz can cause distortion of in-band signals
-Absolute maximum input level without +10dBm attenuation
-5dBm third-order modulation (IIP3) product input intercept point with no internal attenuation
-Compression point from 1dB to -6dBm with no internal attenuation
-Power detector resolution of 0.5dB and linearity versus frequency of +/-1dB
-Absolute power level accuracy after power level calibration of +/- 1dB-Lowest
perceptible signal using 30kHz resolution bandwidth of -115dBm-Frequency
accuracy equal to selected resolution
bandwidth-Pulse-Free dynamic range when using 30kHz resolution bandwidth of 50dB
-Manually selectable resolution filters of 3, 10, 30, 100, 300, 600kHz. Automatic selection of one of 57 resolution
filters—Optional frequency-dependent input attenuator from 25dB to 40dB. The power level error with this attenuator activated increases to +/- 10dB-On-screen
resolution of 51, 101, 145 or 290 measurement
points-Scanning speed of more than 1000 points/second using the highest resolution filters.
-Automatic optimization of the actual scan points to ensure coverage of the entire scan range, regardless of the chosen
resolution bandwidth-After a small HW modification it is possible to listen to the demodulated audio

Low Output Mode Specifications:
-Sinusoidal output with harmonics below -40dB fundamental
-Output frequency range from 100kHz to 350MHz
-Level accuracy +/- 2dB over the entire output frequency range
-Output frequency resolution, either 156 Hz below 47 MHz output or 312 Hz above 47 MHz output
-Output level selectable in 1dB steps between -76dBm and -6dBm
-Optional AM, narrow FM and wide FM modulation with frequencies between 50 Hz and 6 kHz or slow sweep in a selectable frequency range
-Optional output level sweep over the maximum of the entire output level range

High performance mode specifications:
-Square
wave output-Output frequency range from 240 MHz to 960 MHz-Output
frequency resolution, either 156 Hz below the 480 MHz output or 312 Hz above the 480 MHz
output-Selectable output level in variable increments between -38dBm and +9dBm-Optional
narrow FM modulation and wide FM with frequencies between 50 Hz and 6 kHz or slow sweep in a selectable frequency range

     

    ------------------

    Would you like to obtain information about this product?

    Related products

    • Megohmmeter Insulation Resistance Meter Aneng Mh-10

    • Adjustable Voltage Protector Voltage Regulator Sinotimer SVP-912 Screen Voltage Regulator

    • Rs485 Transfer Generator Set Regulator Controller

    • Digital Lighting Light Meter for Ambient Temperature AP-881D

    Contact Us

    Phone number: +1 786 209 1702
    Email: info@northindustriallab.com

    © Copyright - North Industrial Lab LLC - Enfold WordPress Theme by Kriesi
    Link to: Network Network Analyzer Antenna 70/60/50db Nanovna Link to: Network Network Analyzer Antenna 70/60/50db Nanovna Network Network Analyzer Antenna 70/60/50db Nanovna Link to: Vector Network Antenna Analyzer 50khz 3ghz Nanovna V2 Link to: Vector Network Antenna Analyzer 50khz 3ghz Nanovna V2 Vector Network Antenna Analyzer 50khz 3ghz Nanovna V2
    Scroll to top Scroll to top Scroll to top

    Powered by WhatsApp Chat